ULTRA-II-D-TEK

EMX Industries Plug-in Loop Detector (2663-1)

  • Features a slim design that is compatible with most gate operators that require a dry contact relay input.
  • No harness required; comes with terminal screw adaptor
  • ULTRAMETER™ (displays optimum sensitivity setting / diagnostic aid)
  • Frequency count/reset switch
  • 10 sensitivity settings
  • Loop diagnostics
  • 4 operating frequencies
  • Lightning and surge protection
  • Frequency counter
  • Fail safe operation
  • CE compliant
IRB-MON2

EMX Industries Universal Thru-Beam Photocells UL325 Built in Hoods

  • Kit includes transmitter receiver integrated protective hoods and removable lens sunshield
  • Thru beam configuration
  • UL325 compliant
  • Four (4) monitoring interfaces
  • 115 ft. operating range
  • Easy installation and set-up
  • .......more details
IRB-EXP

EMX Industries Explosion Proof Through-Beam Photocells 1162-1

  • Designed to operate in areas with explosive environments.
  • NEMA 4 and 7 housing
  • NEC Class I Groups B C & D Class II Groups E F & G CSA certified CENELEC certified EExd IIC.
  • Copper free Aluminum with Epoxy finish.
  • Potentiometer range adjustment to allow more precise tuning to site.
  • Through beam design is not affected by shiny surfaces.
  • .......more details
IRB-4X2

EMX Nema 4 Through-Beam Photocells EMX-1250-1 Hood Sold Separately

  • The IRB-4X2 photoeye is used as a safety reversing or opening device in conjunction with automatic operators.
  • The IRB-4X2 will work with any control board that accepts dry contact on the input.
  • The easy to install IRB-4X2 is used with garage doors rolling doors parking barriers and other equipment.
  • *Not for use in applications requiring UL325 compliance
  • Thru beam design is not affected by shiny surfaces
  • Wide 24˚ transmission angle allows easier alignment and increases reliability
  • .......more details
LD-11

EMX Base Socket 11-Pin DIN Rail Mountable Black (Was formally Grey)

  • For use with D-TEK detectors (most commonly used)
  • Hourglass shaped
LRS-LC

EMX Logic Controller

  • For use with the Loop Replacement System (LRS-C1) Magnetoresistive Vehicle Detector Control Unit
  • Connects two stand-alone sensors to expand the detection area
  • Works with LRS-DB (LRS-DB-50 or LRS-DB-100) Direct Burial or LRS-FP Flat Pack (LRS-FP-50 or LRS-FP-100)
  • Logic Interface allows one (1) or two (2) sensors to be connected to one (1) output
  • Provides six (6) selectable logic functions and two (2) separate relay outputs
  • A/B directional logic can be selected with an output for each direction of travel as a vehicle passes over two sensors
  • .......more details
LRS-FP-100

EMX Sensor Flat Pack 100ft Wire

  • Lead probe ONLY. Requires the LRS-C1 detector
  • Three-dimensional presence detection of vehicles
  • Select X Y Z axis independently
  • Stand-alone sensor
  • Sensor stores ambient background and settings in non-volatile memory
  • Includes sensor and 100 ft of lead wire
  • .......more details
PROBE-50

EMX CARSENSE-101 Direct Burial Probe with 50' Lead Wire

  • Wand only
  • Requires CS101 (Carsense-101)
PROBE-200

EMX CARSENSE-101 Direct Burial Probe with 200' Lead Wire

  • Wand only
  • Requires CS101 (Carsense-101)
PROBE-150

EMX CARSENSE-101 Direct Burial Probe with 150' Lead Wire

  • Wand only
  • Requires CS101 (Carsense-101)
PROBE-100

EMX CARSENSE-101 Direct Burial Probe with 100' Lead Wire

  • Wand only
  • Requires CS101 (Carsense-101)
LRS-DB-50

EMX Direct Burial Sensor with 50 ft Lead Wire

  • Lead probe ONLY. Requires the LRS-C1 detector
  • Three-dimensional presence detection of vehicles
  • Select X Y Z axis independently
  • Stand-alone sensor
  • Sensor stores ambient background and settings in non-volatile memory
  • Includes direct burial sensor and 100 ft of lead wire
  • .......more details
LRS-DB-100

EMX Direct Burial Sensor with 100 ft Lead Wire

  • Lead probe ONLY. Requires the LRS-C1 detector
  • Three-dimensional presence detection of vehicles
  • Select X Y Z axis independently
  • Stand-alone sensor
  • Sensor stores ambient background and settings in non-volatile memory
  • Includes direct burial sensor and 100 ft of lead wire
  • .......more details
IRB-RET2-KIT

EMX Industries Universal Retroreflective Photoeye Nema 4X W/Reflector Hood New UL325

  • Universal UL325 Retroreflective Photoeye Kit
  • Compact design
  • Easy LED alignment
  • Easy-to-Adjust Ball & Socket Bracket
  • Rugged NEMA 4X enclosure
  • Integrated sensor hood improved reflector hood and ball & socket bracket
  • .......more details
BPE-50

EMX Industries Battery Powered Through-Beam Photocells EMX-1500-1

  • Thru beam configuration
  • 90° adjustment left or right
  • The transmitter and receiver use 12-24 VDC/AC but the BPE-50 can also be powered by two 3.6-volt lithium batteries (Batteries Included)
  • 50 ft. operating range
  • Size: 4.4" (112mm) x 2.05" (52mm) x 1.3" (33mm)
ULT-MVP

EMX Industries Multi-Voltage Loop Detector (ULT-MVP-U)

  • Combines small size with 9VDC to 240VAC input range.
  • Size: 73 x 38 x 78mm
  • ULTRAMETER™ display indicates the appropriate sensitivity setting the vehicle positioned on the loop
  • Ten (10) sensitivity adjustments
  • Four (4) frequency settings
  • Automatic sensitivity boost (ASB) delay fail-safe/fail-secure and infinite or normal (5 min.) presence
  • .......more details
HAR-11

EMX Wiring Harness 11-Pin for D-TEK-MVP 5111-1

  • Universal 11-pin harness
D-TEK-MVP

EMX Industries 9-220 volt Loop Detector 2550-1

  • Wiring harness ( HAR-11) sold separately
  • Warranty 2 years
  • Aluminum RF shield housing
  • Loop diagnostics
  • Frequency counter
  • Control contacts (gold plated)
  • .......more details
ETM17-24V

EMX Digital Timer *** No Longer Available

  • The ETM-17 series are panel mount digital timers the can be operated in 12V dc or 24V ac/dc power supply ranges depending on model ordered.
  • The output is a form “C” relay capable of 16A@ 30VDC.
  • Internal battery for memory backup of programming in the event of power failure.
  • Designed with 17 ON/OFF events per day and 15 combinations of daily programs for the best flexibility to the user.
  • Manual or Auto mode
PTM-24V

EMX 7 Day Programmable Timer 24V

  • The PTM is an easy to program 7 day timer that provides secure access to any facility any time.
  • With up to 16 ON/OFF events per day and 15 different daily options.
  • Its DIN rail mount design and wide power supply options (12 or 24 Volt) make installation easy.
  • The battery backup saves stored programs in the case of power loss.
  • Select either a 12 or 24 hour clock format to program access times for overhead doors gates and parking barriers.
  • The PTM can reduce the wear and tear on motor controls and extend the life of your equipment.
  • .......more details