41A3588-1

LiftMaster Belt Idler Pulley and Bracket (Built Years Pre-2000)

  • €¢This is a Belt Pulley Bracket Replacement Kit. For use with various LiftMaster® and Chamberlain® Belt Drive Garage Door Openers.
  • Works on models 1270. 1280 & 1280R
144B18

LiftMaster Idler Pulley 2" OD 1/2" Bore

  • 144B0018 is a idler pulley (2"OD 1/2"B) replacement kit. Compatible with Models ATS211 & ATS211R garage door openers. Check the manual for your specific model number before ordering.
  • Also known as: 144B0018 144B18
11-10014

LiftMaster Clutch Shaft

  • Commercial door opener clutch shaft
  • 11 7/8" Long; 1/2" Wide
20W33A

LiftMaster Solar Kit 33-AH 12V ***Kit includes: 1x SP20W12V 1x A12330SGLPK & 1x K94-37236***

  • Kit includes: SP20W12V (1) SOLAR-PANEL KIT12V20W A12330SGLPK (1) BATTERY 12V33AHSINGLE K94-37236 (1) UNIVERSAL SOLAR HARNESS KIT-7AH & 33AH
  • Compatible with: RSL12ULMC gate opener
02-711

LiftMaster Nema 7/9 Ceiling Switch Pull Control

  • Single Pull Switch Control
  • Hazardous Area Overhead Mt. (NEMA 7/9)
  • Die cast hazardous area enclosure
  • May be used in two different ways; as an OPEN only control (all LiftMaster operators) or as an OPEN/CLOSE control (only LiftMaster operators with types B2 and S2 control wiring). In the latter case pulling the cord will open a fully closed door close a fully opened door and reverse a closing door.
  • Pulling the cord whlie the door is opening will either have no effect (type B2 wiring) or will stop the door (Solid State Logic Control Board).
  • WARNING: When used on most industrial operators this control will not stop the door. Use another control that has a STOP button in conjunction with this control.
  • .......more details
71-90503000

LiftMaster Non-Resettable Counter Field Kit

  • A 6-digit non-resettable 24VAC electro-mechanical counter is mounted in the operator control enclosure.
  • This devise counts the number of times the CLOSE coil is energized or whenever the operator reaches an auxiliary open limit switch.
  • This corresponds to the number of complete door cycles of use.
41A2825

LiftMaster Opener Assembly Hardware Kit

  • Kit includes screws for various residential chain drive models
50800

LiftMaster RBMA Electric Treadle Nema 4/12 5ft long

  • Five feet long.
  • OPEN only (all LiftMaster operators) or SAFETY only (LiftMaster operators with type B2 C2 L2 T T1 or TS control wiring) after vehicle passes over treadle.
  • The weight of the vehicle compresses an electric switch which sends an open signal to the door.
  • Requires a 2-wire connection to the operator but does not require power to function
050DCTBFLK

LiftMaster Receiver Logic Board DC. WiFi Bluetooth Enabled Lock Capable

  • This is 315MHz Security+ 2.0® Lock Capable Receiver Logic Board featuring Wi-Fi® and powered by myQ®.
  • For use with various LiftMaster® DC Chain or Belt Drive Garage Door Opener models; manufactured after 2017 only.
  • The unit will feature a yellow learn button and two lock terminals
  • Replaces 050DCTWFLK backwards compatible
  • Integrated Bluetooth technology will make it faster and even easier to connect to myQ®
  • Improved opener battery life with increased door usage when operating during a power outage on battery backup mode.
  • .......more details
47DCT

LiftMaster Receiver Logic Board Sec+2.0 Non-MyQ

  • 047DCT is a replacement Security+ 2.0® receiver logic board.
  • This replacement board does not feature MyQ® technology.
  • This 315MHz receiver logic board is compatible with various LiftMaster® AC chain drive and belt drive garage door openers; made after 2011.
  • The unit will feature a yellow learn button.
  • Same as 47DCCR1 47DCCC1 47DCCL1 047DCT41D8060 1D8060
41D0843

LiftMaster Replacement Motor and Sensor 12VDC

  • For Craftsman garage door opener
41D0277-2

LiftMaster Transformer WiFi Non-Battery Backup

  • For Wi-Fi models without BBU garage door openers; manufactured after 2011
  • Same as #204D0277-2
041D8227

LiftMaster Wiring Harness

  • For use with various LiftMaster® Chain Drive Garage Door Openers.
41A7946

LiftMaster Wiring Harness

  • For use with various LiftMaster® Chain / Belt Drive Garage Door Openers.
41C5497

LiftMaster Wiring Harness Kit High Voltage

  • For use with various LiftMaster® and Chamberlain® AC Chain Drive Garage Door Openers; manufactured after 2001
41C5548

LiftMaster Wiring Harness Kit Low Voltage

  • For use with various LiftMaster® and Chamberlain® Garage Door Openers
41C5498

LiftMaster Wiring Harness Kit Low Voltage

  • For use with various LiftMaster® and Chamberlain® AC Chain Drive Garage Door Openers; manufactured after 2001
CPS-OPEN4

LiftMaster Monitored Dual-Sided Photo Eyes

  • For use with sectional or rolling doors.
  • May be installed in areas exposed to rain or moisture
  • Rubberized for more durability
  • Will work on LiftMaster residential operators
K001A5729

LiftMaster Logic 3 Board - L3 ** NLA

  • Open close stop buttons mounted on logic board
  • Selector dial for desired wiring mode
  • Failsafe switch
  • Maintenance Alert System (MAS)
  • Auxiliary reversal system / RPM sensor
  • 014LG0657
  • .......more details
41A2818

LiftMaster Limit Switch Drive Gear Kit

  • For use with various LiftMaster® and Chamberlain® Residential Garage Door Openers.
  • Complete replacement kit includes: helical gear e-clip and grease tube