H-style operators include a floor level chain hoist to ease manual operation in an emergency or power outage.
The operators are typically mounted to the wall when used with larger sectional overhead doors with vertical or high lift and mounted to the wall or the front of the hood when used with rolling doors and grilles.
H operators are attached to the door jackshaft to indirectly drive the door.
MyQ® Technology enables you to securely monitor and control your facility operator and lights with your smartphone tablet or computer for greater peace of mind.
Alerts can be received as email or pop-up (push) notifications on a mobile device ensuring the status of your commercial door.
Security+ 2.0™ safeguards your facility – with every click a new code is sent to the commercial door operator so the door opens only for you.
Suspended from the ceiling the operators are used on sectional overhead doors with standard lift.
T operators are directly attached to drive and control the door.
MyQ® Technology enables you to securely monitor and control your facility operator and lights with your smartphone tablet or computer for greater peace of mind.
Alerts can be received as email or pop-up (push) notifications on a mobile device ensuring the status of your commercial door.
MyQ Mobile App is a free download with no annual activation fee.
H-style operators include a floor level chain hoist to ease manual operation in an emergency or power outage.
The operators are typically mounted to the wall when used with larger sectional overhead doors with vertical or high lift and mounted to the wall or the front of the hood when used with rolling doors and grilles.
H operators are attached to the door jackshaft to indirectly drive the door.
With the addition of the 828LM MyQ technology enables the user to monitor and control their operator and light with their smartphone tablet or computer.
Alerts can be received as email or pop-up (push) notifications on a mobile device ensuring the status of your commercial door.
Security+ 2.0™ safeguards your facility – with every click a new code is sent to the commercial door operator so the door opens only for you.
Light curtain made up of a series of thru-beam photo eyes designed to provide a dense barrier of protection for motorized or high speed doors.
Ideal for environments that require expanded protection for protruding parts that may not be detected by standard single-beam photo eyes mounted 6" above the floor.
Ideal for pre-2010 installations not requiring a monitored solution.
Doors used with this operator should be balanced with the ability to be manually lifted by hand in an emergency or power outage.
The operators are typically mounted to the wall when used with smaller sectional overhead doors with a vertical or high lift and mounted to the wall or the front of the hood when used with rolling doors and grilles.
J operators are attached to the door jackshaft to indirectly drive the door
MyQ® Technology enables you to securely monitor and control your facility operator and lights with your smartphone tablet or computer for greater peace of mind.
Security+ 2.0® safeguards your facility – with every click a new code is sent to the commercial door operator so the door opens only for you
P3 Motors from LiftMaster are reliable durable and powerful – designed specifically for your needs.
Security+ 2.0 – with every click a new code is sent to the garage door opener so that the door opens only for you.
PosiLock locks down your garage door by electronically monitoring against a forced opening.
Alert-2-Close warning system provides audible and visual warnings when the garage door is about to close when using MyQ Technology.
The Protector System has safety sensors that project a light beam across the garage door opening automatically reversing the door if anything interrupts the beam.
Built in Wi-Fi for the easiest way to connect the garage.
Motor and controller: Continuous duty rated DC Motor with controller producing a powerful soft start/soft stop output of 2000 Newtons of force to drive commercial sectional doors while reducing mechanical impacts that cause premature wear of door components
NEMA 4X rated controller case: ZAP Controllers and push buttons are NEMA 4X compliant as a standard
Wiring type: C2 (factory default) B2 failsafe is standard with the addition of approved photo eye.
Radio control and external receiver terminals: Terminal strip provided inside the controller to provide quick convenient connections for adding external radio control receivers from any desired manufacturer
May be used in two different ways: as an OPEN only control (all LiftMaster operators) or as an OPEN/CLOSE control (only LiftMaster operators with types B2 and S2 control wiring).
In the latter case pulling the cord will open a fully closed door close a fully opened door and reverse a closing door.
Pulling the cord whlie the door is opening will either have no effect (type B2 wiring) or will stop the door (Solid State Logic Control Board).
Comes equipped with a built-in 130 degree wide angle camera that features streaming video recording capabilities and two-way communication to the myQ app
Integrated Dual LED Lighting System Ultra-Quiet Belt Drive®
Motor: 12V DC 53 RPM automatic thermal protection
Power: 120V AC 60 Hz voltage 6A current rating
UL Listed 4' power cord (3-prong)