50-104-2

LiftMaster Orange Coil Cord 3-Wire 18-ga 20 ft. Extended Curly Cord

CPS-UN4

LiftMaster Commercial Protector System Thru-Beam Eyes NEMA4

  • Waterproof photoeyes.
  • for direct connect to operators with Logic boards. L3 L4 L5
  • Receiving Eye - A: 50-50997 Sending Eye - A: 50-50998
  • These eyes will also work on the Micanan UL325 monitored operators
CPS-U

LiftMaster Commercial Protector System Eyes

  • For LiftMaster Logic 2 3 4 & 5 commercial operators only
  • NOT for outdoor applications
  • Allows activation of the timer-to-close
  • Mounting hardware included
  • Sensing distance of 30 feet
  • CDO 2010 Ready
  • .......more details
EXTANT

LiftMaster Coax Antenna Connection Kit JF

  • For use on Medium-Duty commercial operators only
CPS3CARD

LiftMaster Option Card Only (41K0811)

  • Works with all commercial Logic versions L2 L3 L4 L5
  • Use with CPS-U to add a second set of eyes to the operator
  • Allows activation of Timer-To-Close without CPS-U
  • Simply plugs into Logic board
  • Cut resistors on JU1 & R16 to activate timer feature
  • Same as 041K0811
  • .......more details
LMWEKITU

LiftMaster Wireless Edge Kit Monitored

  • Meets 2016 UL 325 requirements
  • Innovative industry leading low-energy Bluetooth® transmission up to 130 ft. range
  • Integrated Diagnostics with Gate Operator Speed Installation
  • Protects up to 8 entrapment points
  • Receiver accepts up to 4 transmitters
  • Transmitter accepts up to 2 wired resistive edges
  • .......more details
LOOPDETLM

Liftmaster Plug-in Loop Detector for Liftmaster gate operators

  • Plug-in Loop detector for CSW24V CSL24V AND LA500
  • Includes diagnostic and test feature
  • 12VDC/3mA power draw
  • For exit interrupt or shadow loop applications
  • Activates only when a vehicle passes over a loop
  • 8 sensitivity levels plus boost to ensure that vehicles are easily identified
  • .......more details
CPS-3

LiftMaster Option Card with CPS-L Eyes

  • For applications requiring two sets of photoeyes ( CPS-III)
CPS-RPEN4

LiftMaster Monitored Retro-Reflective Photo Eye with Nema 4 Enclosure for Commercial Door Applications

CPS

LiftMaster Commercial Protector System Eyes

  • Universal commercial photo-eye kit for indoor use
  • Interface box allows CPS to work with all operators
  • 24 volt AC/DC supply voltage
  • Mounting hardware included
  • Sensing distance of 30 feet
  • Receiving Eye - A: 001D6857-1 Sending Eye - A: 001D6857-2
  • .......more details
CPS-UN4G

LiftMaster Commercial Protector System Thru-Beam Eyes NEMA4 Black

  • Waterproof photoeyes.
  • Monitored Thru Beam Photocell
  • For direct connect on HCT
CPS-N4

LiftMaster Nema 4 Commercial Protector System Photo-Eyes with Interface box

  • Commercial Through Beam Photo Eyes includes:
  • 50-15514 I/R Emmitter
  • 50-15515 I/R Detector
  • 77-16011 Hardware Kit N4-CPS
  • 001C4629 CPI Housing Assembly
  • Receiving Eye - A: 50-50997 Sending Eye - A: 50-50998
  • .......more details
LC-36M

LiftMaster Light Curtain Monitored

  • The Monitored Light Curtain is a primary safety entrapment protection device that is compliant with UL 325.
  • IP67 Water-resistant housing anodized aluminum corrosion resistant
  • Operating Temperature: -40° F to +140° F (-40° C to +60° C)
  • Liftmaster Compatibility: LOGIC 5.0 Medium-Duty DDO8900W / LJ8900W / LJ8950W / ATSWVFOH HPH1 / HPH2 HCTDCUL Fire Door Egress
50-450

LiftMaster Interlock Switch for Sectional Door Nema 4 (Same as 50-13529)

  • Interlock switch is engaged by the door side lock and disables operator control.
LM21XPBB

LiftMaster Extended Performance Fire Door Release Device with Battery Backup

  • UL864 Revision 9 compliant
  • Programmable DIP switch delay setting - either 10 20 30 or 60 seconds delay of door release to permit passage clearance
  • Inputs for normally open 2- or 4-wire detectors and 4-wire normally closed detectors
  • Trouble and alarm relays for communication with the fire alarm control panel if required
  • Audible trouble sounder to indicate when the release device is not operational
  • On board diagnostic LEDs for easy troubleshooting
  • .......more details
SP-LMHNTG

LiftMaster Rearview Parking Access Hang Tag 25/pkg Special Coded **Must provide FC & Start #

  • Rearview mirror hanger gives access to gated facilities complexes for cars trucks and other vehicles
  • Can be used for larger vehicles with higher cabs as vans various trucks
  • 20-25 foot detection zone
  • Device is engineered for use with the LIftMaster LMSC1000 Long Range Vehicle Access-Card Reader
  • Simple transferrable item can be swapped out for rental cars different vans/trucks in a fleet dealer/loaner repair cars and more
  • Tags are sold in batches of 25. Your location may have a facility code. Check with your maintenance department or administrator if needed
  • .......more details
S50E-PAIR

LiftMaster Small Profile end kit for one edge only 8.2KOhm resistance

  • Fast easy to install and cost effective system no glue is required
  • One end for output wire other end with resistor for monitoring
  • Compatible with S50 Small Profile Edge
  • Includes: (1) set enough for one edge
  • p/n 1804-1463
Q400MAU

LiftMaster Relay Module

PS12D2A

LiftMaster Passport Power Supply Plug-In 12VDC 2A (02A1699-1/ ST122A)

  • Same as #002A1699-1
02-103L

LiftMaster Push Button Station 3-btn Surface Mount O/C/S Nema 1 with Maintenance Alert LED

  • PBS-3
  • Open-Close-Stop
  • Momentary contact
  • Nema 1
  • Works with Liftmaster MH commercial operator
  • Dimensions: 5-5/16" H x 2-3/8" W x 1-13/16" D
  • .......more details