3BLM-BC

Exterior Control Station 3 Button N4 with Mortise Lockout in Metal Enclose and Best Cylinder

  • Open-Close-Stop
  • Dimensions: 7" h x 2-3/4" w x 3-1/2" d
  • Exterior surface mount
BEA-10-FALCN-XL

BEA Falcon-XL Motion Detector Mount under 11'5"

  • Same features as the Falcon detector but made specifically for extra low mounting
  • Mounting height between 6.5' and 11.5'
  • Detection zone: 13'x6.5' at 8 1/5'
  • Allows uni or bi-directional sensing and the unique ability to open a door when traffic is moving away from the sensor.
  • Sensor also has the ability to differentiate between pedstrians and vehicles.
  • Available remote makes it easy to make adjustments to all key parameters of the sensor while at ground level.
  • .......more details
50150

Doorlec Electro-Mechanical Safety Edge and Weatherstrip Sold per Foot

  • For the protection of vehicles doors and safety of people.
  • Any upward-acting door may be fitted at the leading edge with an electro-mechanical safety weatherstrip.
  • This mechanism consists of a formed galvanized steel section covered with vinyl impregnated rubber hinged along the full width of the leading door edge.
  • Can be adjusted to approximately 2½" (63.5mm) to form a tight weather seal.
  • The hinge linkage is arranged that minimum pressure is required to activate the electrical control switch causing door to reverse direction of travel to the fully open position.
  • Reverse switch is enclosed in a galvanized housing with a sliding plunger to assure positive actuation every time.
  • .......more details
02-103

Push Button Station 3-btn Surface Mount Metal Housing

  • PBS-3
  • Open-Close-Stop
  • Momentary contact
  • Nema 1
  • Dimensions: 5-5/16" H x 2-3/8" W x 1-13/16" D
MK00643

Micanan Auxiliary Apt. Circuit Board for Red/Green Light Feature 115V Models Field Install

  • Auxiliary device logic board
  • Controls red/green lights
  • Provides Normally Open dry contacts for fully open or close positions
  • Normally Open dry conatcs for door opening or door closing cycle
  • Works on circuit boards: MK00641 MK00642 MK00701
  • Includes installation hardware
  • .......more details
02-108

Push Button Station 3-btn O/C/S Flush Mount Stainless Steel Faceplate

  • Nema 1
  • Standard 2X4 electrical junction box with stainless steel faceplate
  • OPEN/CLOSE/STOP allows complete control of the door
LM21XPBB

LiftMaster Extended Performance Fire Door Release Device with Battery Backup

  • UL864 Revision 9 compliant
  • Programmable DIP switch delay setting - either 10 20 30 or 60 seconds delay of door release to permit passage clearance
  • Inputs for normally open 2- or 4-wire detectors and 4-wire normally closed detectors
  • Trouble and alarm relays for communication with the fire alarm control panel if required
  • Audible trouble sounder to indicate when the release device is not operational
  • On board diagnostic LEDs for easy troubleshooting
  • .......more details
50-HERK-RC2

Hercules Infrared Programming Remote Red (50-HERK-RC2)

  • Conveniently choose from 8 different preset comfort functions to adjust detection fields mounting heights relay hold interval cross traffic optimization direction recognition people/vehicle separation slow motion detection turn on/off filter functions open the door manually and much more
  • Bidirectional
  • Fine-tune the motion detector from the ground without guessing if all the settings have been received by the sensor
02-711

LiftMaster Nema 7/9 Ceiling Switch Pull Control

  • Single Pull Switch Control
  • Hazardous Area Overhead Mt. (NEMA 7/9)
  • Die cast hazardous area enclosure
  • May be used in two different ways; as an OPEN only control (all LiftMaster operators) or as an OPEN/CLOSE control (only LiftMaster operators with types B2 and S2 control wiring). In the latter case pulling the cord will open a fully closed door close a fully opened door and reverse a closing door.
  • Pulling the cord whlie the door is opening will either have no effect (type B2 wiring) or will stop the door (Solid State Logic Control Board).
  • WARNING: When used on most industrial operators this control will not stop the door. Use another control that has a STOP button in conjunction with this control.
  • .......more details
TLS1CARD

LiftMaster Option Board for L4 L5

  • Works in conjunction with Logic 4 & Logic 5 to provide seven field-selectable modifications
  • Including six door traffic control options
  • A means to connect External Open & Close limits by using a selectable DIP switch
  • Controls both 24V & 110V traffic lights
  • Formally known as RDGRNCARD
02-411

LiftMaster Pull Switch Assembly Nema 4

  • May be used in two different ways: as an OPEN only control (all LiftMaster operators) or as an OPEN/CLOSE control (only LiftMaster operators with types B2 and S2 control wiring).
  • In the latter case pulling the cord will open a fully closed door close a fully opened door and reverse a closing door.
  • Pulling the cord whlie the door is opening will either have no effect (type B2 wiring) or will stop the door (Solid State Logic Control Board).
02-103L

LiftMaster Push Button Station 3-btn Surface Mount O/C/S Nema 1 with Maintenance Alert LED

  • PBS-3
  • Open-Close-Stop
  • Momentary contact
  • Nema 1
  • Works with Liftmaster MH commercial operator
  • Dimensions: 5-5/16" H x 2-3/8" W x 1-13/16" D
  • .......more details
50800

LiftMaster RBMA Electric Treadle Nema 4/12 5ft long

  • Five feet long.
  • OPEN only (all LiftMaster operators) or SAFETY only (LiftMaster operators with type B2 C2 L2 T T1 or TS control wiring) after vehicle passes over treadle.
  • The weight of the vehicle compresses an electric switch which sends an open signal to the door.
  • Requires a 2-wire connection to the operator but does not require power to function
02-401M

LiftMaster 1-Button Control Station

  • For use with various LiftMaster® Logic 4.0/5.0 and MAXUM Series Commercial Door Operator Applications
  • Sends the door to the full open position. Perfect for time sensitive situations.
02-401

Push Button Control Station 1-Button Surface Mount NEMA 1

  • Die-cast metal enclosure
  • START may be used as OPEN with all LiftMaster operators.
  • May be used as OPEN and CLOSE on all operators with type B2 control wiring
02-409

LiftMaster Key Switch 2-Position Nema 4/12

  • Two Position Key Control Station
  • Outdoor Surface Mt. (NEMA 4/12)
  • Tamperproof
  • Die cast metal enclosure with standard key cylinder
  • OPEN/CLOSE spring return to center (OFF) key removable in center position only. Should only be used on operators wired for constant pressure to open and close (all LiftMaster industrial operators with type D control wiring).
  • Dimiensions: 3" x 3.2" x 4.2"
  • .......more details
02-409B

LiftMaster Key Switch with Best Cylinder

  • Two Position Key Control Station
  • Outdoor Surface Mt. (NEMA 4/12)
  • Tamperproof
  • Die cast metal enclosure with BEST cylinder (construction core included)
  • OPEN/CLOSE spring return to center (OFF) key removable in center position only. Should only be used on operators wired for constant pressure to open and close (all LiftMaster industrial operators with type D control wiring).
  • Dimiensions: 3" x 3.2" x 4.2"
  • .......more details
23-10916

LiftMaster Hoist Interlock Switch SPDT

  • Interlock switch for LM commercial door openers with hoist disconnects
  • 15A 125/250VAC
AFB120

LiftMaster Fire Access Box w/Micro Switch & Knox Key Switch Option

  • ll-in-one fire access box
  • Includes: access door with a hole for a standard or fire department padlock interior micro switch knock out for Knox key switch and standard cylinder lock
  • Two options for automatic gate access: 1) micro switch is activated when the padlock is removed and the front panel is opened or 2) via Knox key switch
  • NOTE: fire department padlock and Knox switch NOT provided
LM56A

LiftMaster Magnetic Proximity Reed Switch

  • Normally Open magnetic sealed reed switch; proximity switch
  • Used for overhead door contacts.