Designed for use as an access control interface for Linear’s block coded digital transmitters.
The unit receives signals from transmitters adds a facility code to the data and sends the information to the Wiegand input of the access control panel via a 5-wire connection
Ideal way to facilitate handicapped access
Multi-button transmitters can double as personal emergency devices for triggering security alarms
RF input/Wiegand output receiver supports 26 30 and 31-bit data formats
Wide selection of MegaCode (over 1 million codes) format transmitters with available block coding
Kit includes PC50CNT20R (emitter) and PC50CNT20RP (reciever)
Operates on 12-240 VDC and 24-240 VAC supply voltage.
The PC50CNT20R has a 3 amp relay output
Adjustable sensitivity modulated infrared light make and break (light/dark) switching function LED indications for output ON signal stability and supply ON
Gearhead style commercial door operators employ lubricated gears for heavy industrial high cycle applications.
GH-style operators include a floor level chain hoist to ease manual operation in an emergency or power outage.
Hoist wheel is easily moved to Right or Left hand side of unit eliminating the need to order right or left hand mounting.
MyQ Technology enables you to securely monitor and control your facility operator with your smartphone tablet or computer. Internet Gateway 828LM required.
Security +2.0 radio receiver safeguards your facility - with every click a new code is sent to the commercial door operator so the door opens only for you.
Timer-To-Close: Conveniently and confidently closes the commercial door automatically after a predetermined amount of time has elapsed for added security and peace of mind.
An Industrial duty operator featuring both the patented Hoist-a-Matic a self-engaging chain hoist for manual operation as well as a floor level disconnect
Specifically designed to motorize grills when a manual egress is required
You can replace the battery with a power supply by removing the SETMC1C9V battery adapter and connect the red (9V)
and black (0V) wire into power supply
Connect a door contact motion detector or any relay activated devices to the SETMC1C9V it will communicate their status wirelessly
The extension kit for C-channel chain drive garage door opener rails is to be used in addition to a 7' (3-piece) chain rail to accommodate an 8' high door
The CarSense 101 provides a solution for many vehicle detection challenges. Where safety is an issue the CarSense 101 detects moving vehicles in blind areas along a driving path and actuates warning lights.
For access control applications requiring free exit the CarSense 101 detects vehicles and actuates gates overhead doors and other parking barriers.
Controls and indicators are mounted on front panel
Available in 9 - 41 VDC 6 - 29 VAC.
Low 2.5 mA standby current consumption makes it an excellent choice for solar power applications.
Die cast metal enclosure with BEST cylinder (construction core included)
OPEN/CLOSE spring return to center (OFF) key removable in center position only. Should only be used on operators wired for constant pressure to open and close (all LiftMaster industrial operators with type D control wiring).
Electromechanical small profile edge for rolling steel foor applicaton.
•Touch sensitive signaling allows for immediate stopping or reversing of motion.
•The MT22 is completely flexible and will contour to curved surfaces. The MT22 also acts as weatherstrip.
•Lead wire: 22 gauge universal
•Sensitivity: nominal 6-8 PSI
•2 wire NO configuration
•Horizontal mount
•ANSI/UL325 recognized component
•One year warranty
H-style operators include a floor level chain hoist to ease manual operation in an emergency or power outage.
The operators are typically mounted to the wall when used with larger sectional overhead doors with vertical or high lift and mounted to the wall or the front of the hood when used with rolling doors and grilles.
H operators are attached to the door jackshaft to indirectly drive the door.
Connectivity
MyQ® Technology enables you to securely monitor and control your facility operator and lights with your smartphone tablet or computer for greater peace of mind.
Alerts can be received as email or pop-up (push) notifications on a mobile device ensuring the status of your commercial door.
H-style operators include a floor level chain hoist to ease manual operation in an emergency or power outage.
The operators are typically mounted to the wall when used with larger sectional overhead doors with vertical or high lift and mounted to the wall or the front of the hood when used with rolling doors and grilles.
H operators are attached to the door jackshaft to indirectly drive the door.
Connectivity
MyQ® Technology enables you to securely monitor and control your facility operator and lights with your smartphone tablet or computer for greater peace of mind.
Alerts can be received as email or pop-up (push) notifications on a mobile device ensuring the status of your commercial door.